Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Single-Unit Short Implants in the Molar Region: A Retrospective Study with a Minimum 3-Year Follow-up
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 42 , Issue 5
September/October 2022

Pages 683–689


Single-Unit Short Implants in the Molar Region: A Retrospective Study with a Minimum 3-Year Follow-up

Eduardo Anitua, MD, DDS, PhD/Javier Flores, DDS/Sofia Fernandez de Retana, PhD/Mohammad Hamdan Alkhraisat, DDS, MSc, PhD, Eu PhD


PMID: 36044701
DOI: 10.11607/prd.5005

The high biomechanical loads in molar region wounds challenge the indication for short implants to be used as a single-unit implant. This study reports on the outcomes of single-unit short implants (≤ 8.0 mm) in the maxillary and mandibular molar regions. Forty-nine short implants were placed in 48 patients to replace a missing molar tooth. Two-piece restorations with screw retention were fabricated. During the follow-up, implant survival and marginal bone loss (MBL) were assessed. The known implant length was used as a reference to calibrate the linear measurements on digital periapical radiographs, and descriptive statistical analysis was performed. The implants were followed over a period of 47 ± 12 months. No implant failure was recorded, and no prosthesis failure was observed. The average MBL was 0.15 ± 0.5 mm. The mean crown height space was 13 ± 3 mm. The overall crown-to-implant ratio was 1.7 ± 0.4. Two technical complications occurred due to the loosening of the unit abutment. After screw re-tightening, no more screw loosening was observed. This study supports the use of short implants as a single-unit implant in the maxillary and mandibular molar regions.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help